Power Battery - 2, 3 and 4 contacts
Dedicated power interfaces spanning single-contact, battery and four-contact high-power connections. Electrical limits belong to the individual version.
Specify this product ↓
Technical values describe the referenced SubConn configuration. DepthLink supply options, final part numbers, dimensions, ratings and mating compatibility require confirmation with your quotation. Pressure-test values are not automatically working-depth ratings.
Applications
- ROV and subsea machinery power
- Battery charging
- Underwater pumps
Configuration notes
The 1 kV and 3 kV versions have different current limits and termination formats. The source recommends insulating oil around the 3 kV bulkhead; agree installation details with the manufacturer.
Electrical & environmental limits
| Voltage rating | 600 V DC/AC rms |
|---|---|
| Current rating | 25 A per contact (max 50 A per connector) |
| Insulation resistance | > 200 MΩ |
| Contact resistance | < 0,01 Ω |
| Wet matings | > 500 |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 800 bar, 11,600 psi (open face) |
| Depth rating | PEEK 300 bar, 4,350 psi |
Materials, cables & terminations
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass, stainless steel, titanium, anodised aluminium or PEEK |
| Contacts | Gold plated brass UNS - C36000 |
| Location pin | Stainless steel AISI 303 |
| O-rings | Nitrile |
| Locking sleeves | POM or stainless steel |
| Snap rings | Stainless steel AISI 302 |
| 2 and 3 conductor inline cable (2 ft, 60 cm) | 10 AWG, 5.26 mm2 synthetic rubber |
| 4 conductor inline cable (2 ft, 60 cm) | 12 AWG, 3.30 mm2 synthetic rubber |
| 2 and 3 contact bulkhead and PBOF leads (1 ft, 30 cm) | 10 AWG, 5.26 mm2 white tagged PTFE |
| 2 and 3 contact OM leads (3", 7 cm) | 10 AWG, 5.26 mm2 white tagged PTFE |
| 4 contact bulkhead and PBOF leads (1 ft, 30 cm) | 12 AWG, 3.31 mm2 white tagged PTFE |
| 4 contact OM leads (3", 7 cm) | 12 AWG, 3.31 mm2 white tagged PTFE |
Wiring & contact references
Contact numbering and wire colours must be checked against the approved drawing for the supplied part.
Inline cable colour code
- 1: Black
- 2: White
- 3: Red
- 4: Green
(3 conductor cable colour code: 1 black, 2 white, 3 green)