Low Profile - 9 contacts
Low-height interfaces for equipment where a projecting connector would obstruct packaging or increase drag. The range includes a separate reed-switch configuration.
Specify this product ↓
Technical values describe the referenced SubConn configuration. DepthLink supply options, final part numbers, dimensions, ratings and mating compatibility require confirmation with your quotation. Pressure-test values are not automatically working-depth ratings.
Applications
- Sensor housings
- Sonar equipment
- ROV instrumentation
Configuration notes
Reed-switch ratings differ from the standard connectors: 200 V DC, 500 mA and 10 W maximum. Do not apply the standard 600 V / 10 A figures to that configuration.
Electrical & environmental limits
| Voltage rating | 600 V DC/AC rms |
|---|---|
| Current rating | 10 A per contact (max 40 A per connector) |
| Insulation resistance | > 200 MΩ |
| Contact resistance | < 0.01 Ω |
| Wet matings | > 500 |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 1,400 bar, 20,300 psi (mated), 800 bar, 11,600 psi (open face) |
| Depth rating PEEK | 300 bar, 4,350 psi |
Materials, cables & terminations
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass, stainless steel, titanium, anodised aluminium or PEEK |
| Contacts | Gold plated brass UNS - C36000 |
| O-rings | Nitrile |
| Locking strap | Chloroprene rubber |
| Inline cable (2 ft, 60 cm or 16 ft, 5 m) | 16 AWG, 1.31 mm2 synthetic rubber |
| Bulkhead leads (1 ft, 30 cm) | 18 AWG, 0.82 mm2 coloured ETFE |
| OM leads (3", 7 cm) | 18 AWG, 0.82 mm2 coloured ETFE |
Wiring & contact references
Contact numbering and wire colours must be checked against the approved drawing for the supplied part.
Inline cable colour code
- 1: Black
- 2: White
- 3: Red
- 4: Green
- 5: Orange
- 6: Blue
- 7: White/black
- 8: Red/black
- 9: Green/black
Mechanical interface & final part identification
Record your required mounting dimensions, thread, cable exit and mating reference in the specification brief below. An approved dimensioned drawing and final supply part number will be confirmed with the quotation. A fabrication or mating drawing is not yet available for this DepthLink alternative.
Low Profile - 9 contacts
Send your enquiry using our contact form or email our team. We can help with product selection, custom configurations, pricing and lead times.