Interface
Height restriction, mounting arrangement and mating access.
Consider a lower-profile connection where installation height is constrained.
Contact us ↗Technical overview ↓
Clearance above the mounting surface and access for mating.
Height restriction, mounting arrangement and mating access.
Cable length, end termination, materials and installation conditions.
Required quantity, delivery date, inspection and documentation.
Final specifications, availability and any compatibility with an existing connector are confirmed during quotation.
Low-height interfaces for equipment where a projecting connector would obstruct packaging or increase drag. The range includes a separate reed-switch configuration.
The figures below describe the referenced SubConn configurations, not verified DepthLink alternatives. Final supplied specifications and mating compatibility are confirmed with your quotation. Qualified pressure-test values are shown as published and are not automatically working-depth ratings.
Technical information reviewed 19 September 2026Reed-switch ratings differ from the standard connectors: 200 V DC, 500 mA and 10 W maximum. Do not apply the standard 600 V / 10 A figures to that configuration.
Expand a group for electrical and environmental limits, construction, wiring. Open the product specification to build your requirements.
| Voltage rating | 600 V DC/AC rms |
|---|---|
| Current rating | 10 A per contact (max 20 A per connector) |
| Insulation resistance | > 200 MΩ |
| Contact resistance | < 0.01 Ω |
| Wet matings | > 500 |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 1,400 bar, 20,300 psi (mated), 800 bar, 11,600 psi (open face) |
| Depth rating PEEK | 300 bar, 4,350 psi |
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass, stainless steel, titanium, anodised aluminium or PEEK |
| Contacts | Gold plated brass UNS - C36000 |
| Location pin | Stainless steel AISI 303 |
| O-rings | Nitrile |
| Locking strap | Chloroprene rubber |
| Inline cable (2 ft, 60 cm) | 16 AWG, 1.31 mm2 synthetic rubber |
| Bulkhead leads (1 ft, 30 cm) | 18 AWG, 0.82 mm2 coloured ETFE |
| OM leads (3", 7 cm) | 18 AWG, 0.82 mm2 coloured ETFE |
Confirm the exact part’s drawing and contact numbering before wiring.
| Voltage rating | 600 V DC/AC rms |
|---|---|
| 3 contacts current rating | 10 A per contact (max 30 A per connector) |
| 4 contacts current rating | 10 A per contact (max 40 A per connector) |
| Insulation resistance | > 200 MΩ |
| Contact resistance | < 0.01 Ω |
| Wet matings | > 500 |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 1,400 bar, 20,300 psi (mated), 800 bar, 11,600 psi (open face) |
| Depth rating PEEK | 300 bar, 4,350 psi |
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass, stainless steel, titanium, anodised aluminium or PEEK |
| Contacts | Gold plated brass UNS - C36000 |
| O-rings | Nitrile |
| Locking strap | Chloroprene rubber |
| Inline cable (2 ft, 60 cm or 16 ft, 5 m) | 16 AWG, 1.31 mm2 synthetic rubber |
| Bulkhead leads (1 ft. 30 cm) | 18 AWG, 0.82 mm2 coloured ETFE |
| OM leads (3", 7 cm) | 18 AWG, 0.82 mm2 coloured ETFE |
Confirm the exact part’s drawing and contact numbering before wiring.
| Voltage rating | 600 V DC/AC rms |
|---|---|
| Current rating | 10 A per contact (max 40 A per connector) |
| Insulation resistance | > 200 MΩ |
| Contact resistance | < 0.01 Ω |
| Wet matings | > 500 |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 1,400 bar, 20,300 psi (mated), 800 bar, 11,600 psi (open face) |
| Depth rating PEEK | 300 bar, 4,350 psi |
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass, stainless steel, titanium, anodised aluminium or PEEK |
| Contacts | Gold plated brass UNS - C36000 |
| O-rings | Nitrile |
| Locking strap | Chloroprene rubber |
| Inline cable (2 ft, 60 cm or 16 ft, 5 m) | 18 AWG, 0.82 mm2 synthetic rubber |
| Bulkhead leads (1 ft, 30 cm) | 18 AWG, 0.82 mm2 coloured ETFE |
| OM leads (3", 7 cm) | 18 AWG, 0.82 mm2 coloured ETFE |
Confirm the exact part’s drawing and contact numbering before wiring.
| Voltage rating | 600 V DC/AC rms |
|---|---|
| Current rating | 10 A per contact (max 40 A per connector) |
| Insulation resistance | > 200 MΩ |
| Contact resistance | < 0.01 Ω |
| Wet matings | > 500 |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 1,400 bar, 20,300 psi (mated), 800 bar, 11,600 psi (open face) |
| Depth rating PEEK | 300 bar, 4,350 psi |
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass, stainless steel, titanium, anodised aluminium or PEEK |
| Contacts | Gold plated brass UNS - C36000 |
| O-rings | Nitrile |
| Locking strap | Chloroprene rubber |
| Inline cable (2 ft, 60 cm) | 16 AWG, 1.31 mm2 synthetic rubber |
| Bulkhead leads (1 ft, 30 cm) | 18 AWG, 0.82 mm2 coloured ETFE |
| OM leads (3", 7 cm) | 18 AWG, 0.82 mm2 coloured ETFE |
Confirm the exact part’s drawing and contact numbering before wiring.
| Voltage rating | 600 V DC/AC rms |
|---|---|
| Current rating | 10 A per contact (max 40 A per connector) |
| Insulation resistance | > 200 MΩ |
| Contact resistance | < 0.01 Ω |
| Wet matings | > 500 |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 1,400 bar, 20,300 psi (mated), 800 bar, 11,600 psi (open face) |
| Depth rating PEEK | 300 bar, 4,350 psi |
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass, stainless steel, titanium, anodised aluminium or PEEK |
| Contacts | Gold plated brass UNS - C36000 |
| O-rings | Nitrile |
| Locking strap | Chloroprene rubber |
| Inline cable (2 ft, 60 cm or 16 ft, 5 m) | 16 AWG, 1.31 mm2 synthetic rubber |
| Bulkhead leads (1 ft, 30 cm) | 18 AWG, 0.82 mm2 coloured ETFE |
| OM leads (3", 7 cm) | 18 AWG, 0.82 mm2 coloured ETFE |
Confirm the exact part’s drawing and contact numbering before wiring.
| Reed switch glass body type | HE559-ND |
|---|---|
| Switch voltage rating | 200 V DC |
| Contact rating | 10 W max |
| Switch current rating | 500 mA |
| Operation time | 0.6 ms (maximum) |
| Release time | 0.2 ms (maximum) |
| Capacitance | 0.20 pF (typical) |
| Contact resistance | < 0.01 Ω |
| Wet matings | > 500 |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Depth rating | 300 bar, 4,350 psi (open face) |
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass or stainless steel |
| Contacts | Gold plated brass UNS - C36000 |
| O-rings | Nitrile |
| Locking strap | Chloroprene rubber |
| Inline cable (2 ft, 60 cm) | 16 AWG, 1.31 mm2 synthetic rubber |
Confirm the exact part’s drawing and contact numbering before wiring.
Share your current manufacturer and part number. We’ll review a suitable option for your application.

A starting point for general subsea equipment connections.
Explore requirements
Explore compact circular connections for instruments and smaller assemblies.
Explore requirements
Define a compact connection for closely packaged equipment.
Explore requirements
Explore metal-shell configurations around your mechanical and environmental requirements.
Explore requirements
Specify the connection around your equipment’s power requirements.
Explore requirements
Define the complete signal path for your data connection.
Explore requirements
Discuss coaxial connections as part of a complete cable and equipment interface.
Explore requirements
Explore miniature connections for space-sensitive sensing and instrumentation.
Explore requirementsDefine the connector, cable and termination together.