Interface
Impedance, frequency, cable type and signal requirements.
Discuss coaxial connections as part of a complete cable and equipment interface.
Contact us ↗Technical overview ↓
Impedance, frequency range and signal-path requirements.
Impedance, frequency, cable type and signal requirements.
Cable length, end termination, materials and installation conditions.
Required quantity, delivery date, inspection and documentation.
Final specifications, availability and any compatibility with an existing connector are confirmed during quotation.
Coaxial signal connections offered at 50 or 75 Ω, either coax-only or with six additional electrical contacts.
The figures below describe the referenced SubConn configurations, not verified DepthLink alternatives. Final supplied specifications and mating compatibility are confirmed with your quotation. Qualified pressure-test values are shown as published and are not automatically working-depth ratings.
Technical information reviewed 19 September 2026Not suitable for open-face pressure or waterblock applications. Locking sleeves are required. Published attenuation describes a 10 m cable assembly including two bulkheads, not the connector alone. Minimum inline cable bend radius: 100 mm; keep grease off the coax interface.
Expand a group for electrical and environmental limits, construction, wiring. Open the product specification to build your requirements.
| Voltage rating on coax insert only | 800 V, max nominal voltage |
|---|---|
| Frequency* | 0.3 GHz / 0.6 GHz / 0.9 GHz / 1.2 GHz / 1.5 GHz / 1.8 GHz / 2.1 GHz / 2.4 GHz / 2.7 GHz / 3.0 GHz |
| Attenuation* | 5.0 dB / 7.7 dB / 9.9 dB / 11.6 dB / 13.4 dB / 15.3 dB / 17.3 dB / 19.3 dB / 21 dB / 22.5 dB |
| Recommended max frequency | 3.0 GHz |
| Insulation resistance | > 200 MΩ |
| Contact resistance | < 0.01 Ω |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 600 bar, 8,700 psi (mated) |
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass, stainless steel, titanium or anodised aluminium |
| Bulkhead body (RA) | Brass, stainless steel, titanium or anodised aluminium |
| Coax contacts | Gold plated contacts |
| O-rings | Nitrile |
| Locking sleeves | POM or stainless steel |
| Locking sleeves (RA) | RADLSA-M (black POM) |
| Snap rings | Stainless steel AISI 302 |
| Inline cable (2 ft, 60 cm) | PUR jacket cable with RG58 coax |
| Coax bulkhead leads (3.3 ft, 100 cm) | RG316 coax |
Frequency and attenuation values refer to a 10 m assembly with two bulkheads. Dry mate only; not for open-face pressure or waterblock use. Locking sleeves required.
| Voltage rating on electric contacts | 300 V DC/AC rms |
|---|---|
| Current rating on electric contacts | 5 A per contact (max 20 A per connector) |
| Voltage rating on coax | 800 V, max nominal voltage |
| Frequency* | 0.3 GHz / 0.6 GHz / 0.9 GHz / 1.2 GHz / 1.5 GHz / 1.8 GHz / 2.1 GHz / 2.4 GHz / 2.7 GHz / 3.0 GHz |
| Attenuation* | 5.0 dB / 7.7 dB / 9.9 dB / 11.6 dB / 13.4 dB / 15.3 dB / 17.3 dB / 19.3 dB / 21 dB / 22.5 dB |
| Recommended max frequency | 3.0 GHz |
| Insulation resistance | > 200 MΩ |
| Contact resistance | < 0.01 Ω |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 600 bar, 8,700 psi (mated) |
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass, stainless steel, titanium or anodised aluminium |
| Bulkhead body (RA) | Brass, stainless steel, titanium or anodised aluminium |
| Power contacts | Female sockets in gold plated brass UNS - C36000, Male contacts in gold plated beryllium copper |
| Coax contacts | Gold plated contacts |
| O-rings | Nitrile |
| Locking sleeves | POM or stainless steel |
| Locking sleeves (RA) | RADLSA-M (black POM) |
| Snap rings | Stainless steel AISI 302 |
| Inline cable (2 ft, 60 cm) | RG58 coax and 6 x 20 AWG, 0.52 mm2 conductors |
| Coax and 6-contact bulkhead leads (3.3 ft, 100 cm) | RG316 coax and 6 x 20 AWG, 0.52 mm2 coloured PTFE |
Confirm the exact part’s drawing and contact numbering before wiring.
Frequency and attenuation values refer to a 10 m assembly with two bulkheads. Dry mate only; not for open-face pressure or waterblock use. Locking sleeves required.
| Voltage rating on coax insert only | 600 V, max nominal voltage |
|---|---|
| Frequency* | 0.9 GHz / 1.2 GHz / 1.5 GHz / 1.8 GHz / 2.1 GHz / 2.4 GHz / 2.7 GHz / 3.0 GHz |
| Attenuation* | 6.3 dB / 7.4 dB / 8.6 dB / 9.9 dB / 11.3 dB / 12.8 dB / 14.5 dB / 15.7 dB |
| Recommended max frequency | 3.0 GHz |
| Insulation resistance | > 200 MΩ |
| Contact resistance | < 0.01 Ω |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 600 bar, 8,700 psi (mated) |
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass, stainless steel, titanium or anodised aluminium |
| Bulkhead body (RA) | Brass, stainless steel, titanium or anodised aluminium |
| Coax contacts | Gold plated contacts |
| O-rings | Nitrile |
| Locking sleeves | POM or stainless steel |
| Locking sleeves (RA) | RADLSA-M (black POM) |
| Snap rings | Stainless steel AISI 302 |
| Inline cable (2 ft, 60 cm) | PUR jacket cable with Mini-RG59 coax |
| Coax bulkhead leads (3.3 ft, 100 cm) | RG179 coax |
Frequency and attenuation values refer to a 10 m assembly with two bulkheads. Dry mate only; not for open-face pressure or waterblock use. Locking sleeves required.
| Voltage rating on electric contacts | 300 V DC/AC rms |
|---|---|
| Current rating on electric contacts | 5 A per contact (max 20 A per connector) |
| Voltage rating on coax insert only | 600 V, max nominal voltage |
| Frequency* | 0.9 GHz / 1.2 GHz / 1.5 GHz / 1.8 GHz / 2.1 GHz / 2.4 GHz / 2.7 GHz / 3.0 GHz |
| Attenuation* | 6.3 dB / 7.4 dB / 8.6 dB / 9.9 dB / 11.3 dB / 12.8 dB / 14.5 dB / 15.7 dB |
| Recommended max frequency | 3.0 GHz |
| Insulation resistance | > 200 MΩ |
| Contact resistance | < 0.01 Ω |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 600 bar, 8,700 psi (mated) |
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass, stainless steel, titanium or anodised aluminium |
| Bulkhead body (RA) | Brass, stainless steel, titanium or anodised aluminium |
| Power contacts | Female sockets in gold plated brass UNS - C36000, Male contacts in gold plated beryllium copper |
| Coax contacts | Gold plated contacts |
| O-rings | Nitrile |
| Locking sleeves | POM or stainless steel |
| Locking sleeves (RA) | RADLSA-M (black POM) |
| Snap rings | Stainless steel AISI 302 |
| Inline cable (2 ft, 60 cm) | Mini-RG59 coax and 6 x 20 AWG, 0.52 mm2 conductors |
| Coax and 6-contact bulkhead leads (3.3 ft, 100 cm) | RG179 coax and 6 x 20 AWG, 0.52 mm2 coloured PTFE |
Confirm the exact part’s drawing and contact numbering before wiring.
Frequency and attenuation values refer to a 10 m assembly with two bulkheads. Dry mate only; not for open-face pressure or waterblock use. Locking sleeves required.
Share your current manufacturer and part number. We’ll review a suitable option for your application.

A starting point for general subsea equipment connections.
Explore requirements
Explore compact circular connections for instruments and smaller assemblies.
Explore requirements
Consider a lower-profile connection where installation height is constrained.
Explore requirements
Define a compact connection for closely packaged equipment.
Explore requirements
Explore metal-shell configurations around your mechanical and environmental requirements.
Explore requirements
Specify the connection around your equipment’s power requirements.
Explore requirements
Define the complete signal path for your data connection.
Explore requirements
Explore miniature connections for space-sensitive sensing and instrumentation.
Explore requirementsDefine the connector, cable and termination together.