Interface
Envelope drawing, cable exit direction, pin count and bend radius.
Define a compact connection for closely packaged equipment.
Contact us ↗Technical overview ↓
The complete installed envelope, including cable exit and bend radius.
Envelope drawing, cable exit direction, pin count and bend radius.
Cable length, end termination, materials and installation conditions.
Required quantity, delivery date, inspection and documentation.
Final specifications, availability and any compatibility with an existing connector are confirmed during quotation.
A smaller low-profile format for tightly packaged underwater sensors and instruments.
The figures below describe the referenced SubConn configurations, not verified DepthLink alternatives. Final supplied specifications and mating compatibility are confirmed with your quotation. Qualified pressure-test values are shown as published and are not automatically working-depth ratings.
Technical information reviewed 19 September 2026The 7/9-contact page gives an 800 bar qualified pressure-test value without stating the mating condition in that row. Confirm the applicable condition before specifying.
Expand a group for electrical and environmental limits, construction, wiring. Open the product specification to build your requirements.
| Voltage rating | 300 V DC/AC rms |
|---|---|
| Current rating | 5 A per contact (max 10 A per connector) |
| Insulation resistance | > 200 MΩ |
| Contact resistance | < 0.01 Ω |
| Wet matings | > 500 |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 1,400 bar, 20,300 psi (mated) 800 bar, 11,600 psi (open face) |
| Depth rating PEEK | 300 bar, 4,350 psi |
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass or stainless steel |
| Contacts | Female sockets in gold plated brass UNS - C36000 Male contacts in gold plated beryllium copper |
| O-rings | Nitrile |
| Locking strap | Chloroprene rubber |
| Inline cable (2 ft, 60 cm) | 20 AWG, 0.52 mm2 synthetic rubber |
| Bulkhead leads (1 ft, 30 cm) | 20 AWG, 0.52 mm2 coloured PTFE |
Confirm the exact part’s drawing and contact numbering before wiring.
| Voltage rating | 300 V DC/AC rms |
|---|---|
| Current rating | 5 A per contact (max 20 A per connector) |
| Insulation resistance | > 200 Mohm |
| Contact resistance | < 0.01 ohm |
| Wet matings | > 500 (open face rated) |
| Temperature rating (water) | - 4 to 60˚C, 25 to 140˚F |
| Temperature rating (air) | - 40 to 60˚C, - 40 to 140˚F |
| Storage temperature rating | - 40 to 60˚C, - 40 to 140˚F |
| Qualified pressure tested | 800 bar, 11,600 psi |
| Depth rating PEEK | 300 bar, 4,350 psi |
| Connector body | Chloroprene rubber |
|---|---|
| Bulkhead body | Brass, stainless steel, titanium, anodised aluminium or PEEK |
| Contacts | Female sockets in gold plated brass UNS - C36000, Male pins in gold plated beryllium copper |
| O-rings | Nitrile |
| Locking strap | Chloroprene rubber |
| Inline cable (2 ft, 60 cm) | 20 AWG, 0.52 mm2 synthetic rubber |
| Bulkhead leads (1 ft, 30 cm) | 20 AWG, 0.52 mm2 coloured PTFE |
| OM leads (3", 7 cm) | 20 AWG, 0.52 mm2 coloured PTFE |
Confirm the exact part’s drawing and contact numbering before wiring.
Share your current manufacturer and part number. We’ll review a suitable option for your application.

A starting point for general subsea equipment connections.
Explore requirements
Explore compact circular connections for instruments and smaller assemblies.
Explore requirements
Consider a lower-profile connection where installation height is constrained.
Explore requirements
Explore metal-shell configurations around your mechanical and environmental requirements.
Explore requirements
Specify the connection around your equipment’s power requirements.
Explore requirements
Define the complete signal path for your data connection.
Explore requirements
Discuss coaxial connections as part of a complete cable and equipment interface.
Explore requirements
Explore miniature connections for space-sensitive sensing and instrumentation.
Explore requirementsDefine the connector, cable and termination together.